Dolycon CT113 series special inverter is based on the hardware platform of Dolycon vector inverter CT100G. It is
equipped with mains synchronization function and widely applied in medium power, shore power, fire
emergency power and the power system of public facilities in subway, airport, hospital and large shopping
mall.
CT113 series special inverter Benefits:
V/F separate control function to satisfy industry craft requirements.
Automatically search and follow resonance points to ensure real-time system efficiency.
Switch voltage lock and current lock modes to meet different industrial requirements.
Input voltage: 3PH 380VAC±15%.
Input frequency: 50~60Hz±5%
Output voltage: 0~Rated input voltage
Output frequency: 50~8000Hz
Control mode: current control, voltage control
Overload capacity:150% of rated current: 60s;
180% of rated current: 10s;
200% of rated current: 1s
ACC and DEC time:0.1~3000.0s
Frequency setting:Keypad setting, analog quantity setting, multi-step speed setting, PID setting, 485 communication setting
Output voltage setting method:Keypad setting, analog quantity setting, multi-step speed setting, PID setting, 485 communication setting
Parameters
Select the channel for the intermediate frequency power start-stop control command. The middle power control commands include: start, stop. 0: The keypad/panel runs the command channel, and the
intermediate frequency power operation, shutdown, forward and reverse or jog is controlled through the
buttons RUN, STOP/RESET or MF on the operation panel. 1: Terminal operation command channel, by
defining the multi-function input terminal DI1~DI5 switch selection forward, reverse, jogging, etc. for
intermediate frequency power supply operation control. Refer to (F06.01~F06.05). 2: 485 run the
command channel, through RS485 communication, from the host computer to the intermediate frequency
power start and stop command.